-PERMISSIBLE LOADS ON HORIZONTAL COMPONENTS
Permissible loads on the various components are shown in the diagrams . 


-PERMISSIBLE LOADS ON VERTICALS( IN FALSEWORK SERUCTURES ONLY )

The permissible loads on verticals in Falsework Structures incorporating suitable bracing
listed below are based upon maximum 2.5m length bay . However , permissible loads

depend on a number of factors and reference should be made to our Technical Department.

.

Vertical loading(KN)

Main lift (m)

End

Internal

57.0

57.0

1.0

42.0

45.0

1.5

29.0

33.0

2.0

20.0

23.0

2.5

For practical purposes divide load in kN by 10 to convert to tonnes or tons .

For further information on the design of "A" LOK  Access and Support Scaffolds please

contact our TechnicalDepartment .


-PERMISSIBLE LOADS ON BASE COMPONENTS

The loading will vary according to the horizontal loads taken into account and the actual