Loading... Please wait...-PERMISSIBLE LOADS ON HORIZONTAL COMPONENTS
Permissible loads on the various components are shown in the diagrams .
-PERMISSIBLE LOADS ON VERTICALS( IN FALSEWORK SERUCTURES ONLY )
The permissible loads on verticals in Falsework Structures incorporating suitable bracing
listed below are based upon maximum 2.5m length bay . However , permissible loads
depend on a number of factors and reference should be made to our Technical Department.
.
|
Vertical loading(KN) |
Main lift (m) |
|
|
End |
Internal |
|
|
57.0 |
57.0 |
1.0 |
|
42.0 |
45.0 |
1.5 |
|
29.0 |
33.0 |
2.0 |
|
20.0 |
23.0 |
2.5 |
For practical purposes divide load in kN by 10 to convert to tonnes or tons .
For further information on the design of "A" LOK Access and Support Scaffolds please
contact our TechnicalDepartment .
-PERMISSIBLE LOADS ON BASE COMPONENTS
The loading will vary according to the horizontal loads taken into account and the actual
extension of the Jack required .